New in version 2.2.
Execute vlag-create/vlag-delete/vlag-modify command. A virtual link aggregation group (VLAG) allows links that are physically connected to two different Pluribus Networks devices to appear as a single trunk to a third device. The third device can be a switch, server, or any Ethernet device. A VLAG can provide Layer 2 multipathing, which allows you to create redundancy by increasing bandwidth, enabling multiple parallel paths between nodes and loadbalancing traffic where alternative paths exist.
parameter | required | default | choices | comments |
---|---|---|---|---|
pn_clipassword | no | Provide login password if user is not root. |
||
pn_cliswitch | no | Target switch(es) to run this command on. |
||
pn_cliusername | no | Provide login username if user is not root. |
||
pn_failover_action | no |
| Specify the failover action as move or ignore. |
|
pn_lacp_fallback | no |
| Specify the LACP fallback mode as bundles or individual. |
|
pn_lacp_fallback_timeout | no | Specify the LACP fallback timeout in seconds. The range is between 30 and 60 seconds with a default value of 50 seconds. |
||
pn_lacp_mode | no |
| Specify the LACP mode. |
|
pn_lacp_timeout | no |
| Specify the LACP timeout as slow(30 seconds) or fast(4 seconds). |
|
pn_mode | no |
| Specify the mode for the VLAG. Active-standby indicates one side is active and the other side is in standby mode. Active-active indicates that both sides of the vlag are up by default. |
|
pn_name | yes | The pn_name takes a valid name for vlag configuration. |
||
pn_peer_port | no |
Specify the peer VLAG port.
Required for vlag-create.
|
||
pn_peer_switch | no | Specify the fabric-name of the peer switch. |
||
pn_port | no |
Specify the local VLAG port.
Required for vlag-create.
|
||
state | yes |
| State the action to perform. Use 'present' to create vlag, 'absent' to delete vlag and 'update' to modify vlag. |
- name: create a VLAG pn_vlag: state: 'present' pn_name: spine-to-leaf pn_port: 'spine01-to-leaf' pn_peer_port: 'spine02-to-leaf' pn_peer_switch: spine02 pn_mode: 'active-active' - name: delete VLAGs pn_vlag: state: 'absent' pn_name: spine-to-leaf
Common return values are documented here Common Return Values, the following are the fields unique to this module:
name | description | returned | type | sample |
---|---|---|---|---|
changed | Indicates whether the CLI caused changes on the target. | always | bool | |
command | The CLI command run on the target node(s). | |||
stderr | The set of error responses from the vlag command. | on error | list | |
stdout | The set of responses from the vlag command. | always | list |
For more information on what this means please read Core Modules
For help in developing on modules, should you be so inclined, please read Community Information & Contributing, developing_test_pr and Developing Modules.
© 2012–2016 Michael DeHaan
© 2016 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/pn_vlag_module.html