New in version 2.1.
Configures a bond interface on Cumulus Linux To configure a bridge port use the cl_bridge module. To configure any other type of interface use the cl_interface module. Follow the guidelines for bonding found in the Cumulus User Guide at http://docs.cumulusnetworks.com.
parameter | required | default | choices | comments |
---|---|---|---|---|
addr_method | no |
| Configures the port to use DHCP. To enable this feature use the option dhcp. |
|
alias_name | no | Description of the port. |
||
clag_id | no | Specify a unique clag_id for every dual connected bond on each peer switch. The value must be between 1 and 65535 and must be the same on both peer switches in order for the bond to be considered dual-connected. |
||
ipv4 | no | List of IPv4 addresses to configure on the interface. In the form X.X.X.X/YY. |
||
ipv6 | no | List of IPv6 addresses to configure on the interface. In the form X:X:X::X/YYY. |
||
lacp_bypass_all_active | no | Activate all interfaces for bypass. It is recommended to configure all_active instead of using bypass_priority. |
||
lacp_bypass_allow | no | Enable LACP bypass. |
||
lacp_bypass_period | no | Period for enabling LACP bypass. Max value is 900. |
||
lacp_bypass_priority | no | List of ports and priorities. Example "swp1=10, swp2=20". |
||
lacp_rate | no | 1 | The lacp rate. |
|
location | no | [u'/etc/network/interfaces.d'] | Interface directory location. |
|
miimon | no | 100 | The mii link monitoring interval. |
|
min_links | no | 1 | Minimum number of links. |
|
mode | no | 802.3ad | The bond mode, as of Cumulus Linux 2.5 only LACP bond mode is supported. |
|
mstpctl_bpduguard | no |
| Enables BPDU Guard on a port in vlan-aware mode. |
|
mstpctl_portadminedge | no |
| Enables admin edge port. |
|
mstpctl_portnetwork | no |
| Enables bridge assurance in vlan-aware mode. |
|
mtu | no | Set MTU. Configure Jumbo Frame by setting MTU to 9000. |
||
name | yes | Name of the interface. |
||
pvid | no | In vlan-aware mode, defines vlan that is the untagged vlan. |
||
slaves | yes | Bond members. |
||
vids | no | In vlan-aware mode, lists VLANs defined under the interface. |
||
virtual_ip | no | Define IPv4 virtual IP used by the Cumulus Linux VRR feature. |
||
virtual_mac | no | Define Ethernet mac associated with Cumulus Linux VRR feature. |
||
xmit_hash_policy | no | layer3+4 | Transmit load balancing algorithm. As of Cumulus Linux 2.5 only layer3+4 policy is supported. |
# Options ['virtual_mac', 'virtual_ip'] are required together # configure a bond interface with IP address cl_bond: name=bond0 slaves="swp4-5" ipv4=10.1.1.1/24 notify: reload networking # configure bond as a dual-connected clag bond cl_bond: name=bond1 slaves="swp1s0 swp2s0" clag_id=1 notify: reload networking # define cl_bond once in tasks file # then write interface config in variables file # with just the options you want. cl_bond: name: "{{ item.key }}" slaves: "{{ item.value.slaves }}" clag_id: "{{ item.value.clag_id|default(omit) }}" ipv4: "{{ item.value.ipv4|default(omit) }}" ipv6: "{{ item.value.ipv6|default(omit) }}" alias_name: "{{ item.value.alias_name|default(omit) }}" addr_method: "{{ item.value.addr_method|default(omit) }}" mtu: "{{ item.value.mtu|default(omit) }}" vids: "{{ item.value.vids|default(omit) }}" virtual_ip: "{{ item.value.virtual_ip|default(omit) }}" virtual_mac: "{{ item.value.virtual_mac|default(omit) }}" mstpctl_portnetwork: "{{ item.value.mstpctl_portnetwork|default('no') }}" mstpctl_portadminedge: "{{ item.value.mstpctl_portadminedge|default('no') }}" mstpctl_bpduguard: "{{ item.value.mstpctl_bpduguard|default('no') }}" with_dict: cl_bonds notify: reload networking # In vars file # ============ cl_bonds: bond0: alias_name: 'uplink to isp' slaves: ['swp1', 'swp3'] ipv4: '10.1.1.1/24' bond2: vids: [1, 50] clag_id: 1
Common return values are documented here Common Return Values, the following are the fields unique to this module:
name | description | returned | type | sample |
---|---|---|---|---|
msg | human-readable report of success or failure | always | string | interface bond0 config updated |
changed | whether the interface was changed | changed | bool | True |
Note
As this module writes the interface directory location, ensure that /etc/network/interfaces
has a ‘source /etc/network/interfaces.d/*’ or whatever path is mentioned in the location
attribute.
Note
For the config to be activated, i.e installed in the kernel, “service networking reload” needs be be executed. See EXAMPLES section.
For more information on what this means please read Core Modules
For help in developing on modules, should you be so inclined, please read Community Information & Contributing, developing_test_pr and Developing Modules.
© 2012–2016 Michael DeHaan
© 2016 Red Hat, Inc.
Licensed under the GNU General Public License version 3.